ST-C

Needle valve, cartridge type
ST-C
Download the PDF
NEEDLE
ST-C
Needle valve, cartridge type
Maximum flow 40 l/min
Maximum pressure 350 bar
Installation torque

27÷30 Nm

 
 

Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm

code
description
max. flow rate
max. pressure
cavities
3dfiles

(ordering initials)

l/min

gpm

bar

psi

RF000051
STCA 20X1,5
40
10.57
300
4351
RF000052
STCB 20X1,5
40
10.57
300
4351