VLP40-D-FMD-SF-VC

Double effect antishock valve with brake unclampign, nipple screw flangeable to DANFOSS OMP-OMR motor
VLP40-D-FMD-SF-VC
Download the PDF
DANFOSS
VLP40-D-FMD-SF-VC
Double effect antishock valve with brake unclampign, nipple screw flangeable to DANFOSS OMP-OMR motor
Maximum flow 40 l/min
Maximum pressure 300 bar
Taratura
Code Standard setting
bar (Q= 5l/min)
Adj. Pressure range
bar
00 40 5÷40
01 80 20÷100
02 180 40÷250
03 250 60÷350
 

Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm