VSQ1030-C

3 Ways Pilot operated sequence valve - cartridge type
VSQ1030-C
Download the PDF
SEQUENCE
VSQ1030-C
3 Ways Pilot operated sequence valve - cartridge type
Maximum flow 40 l/min
10.5 gpm
Maximum pressure 350 bar
5000 psi
Installation torque 45÷50 Nm
33÷37 lbf ft 
Setting
Code Standard setting Adj. pressure range Pressure increase
bar * turn
01 60 bar
870 psi
10÷80 bar
145÷1160 psi
14
02 80 bar
1160 psi
10÷120 bar
145÷1750 psi
34
03 120 bar
1750 psi
20÷160 bar
290÷2300 psi

55

Performances and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C (122 F).
Recommended viscosity 10 ÷420 cSt, working temperature -20÷+90 °C (-4 F÷194 F). Absolute filtration 25 μ.

code
description
max. flow rate
max. pressure
cavities

(ordering initials)

l/min

gpm

bar

psi

VSQ00218
VSQ1030C01A
40
10.57
350
5076
VSQ00219
VSQ1030C02A
40
10.57
350
5076
VSQ00179
VSQ1030C03A
40
10.57
350
5076