| Maximum flow | 70 l/min 18.5 gpm |
| Maximum pressure | 350 bar 5000 psi |
| Installation torque | 45÷50 Nm 33÷37 lbf ft |
| Setting | |||
| Code | Standard setting | Adj. pressure range | Pressure increase |
| 01 | 80 bar 1160 psi |
20÷100 bar 290÷1450 psi |
23 bar 333 psi |
| 02 | 180 bar 2600 psi |
40÷250 bar |
56 bar 810 psi |
| 03 | 250 bar 3600 psi |
60÷350 bar 870÷5000 psi |
91 bar 1320 psi |
Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm
(ordering initials)
l/min
gpm
bar
psi