| Type | P, T | Max pressure [bar] | Max flow [l/min] |
| VLP5-18 | 1/8" GAS | 350 | 5 |
| VLP40-14 | 1/4" GAS | 350 | 25 |
| VLP40-38 | 3/8"GAS | 350 | 35 |
| VLP40-12 | 1/2"GAS | 350 | 40 |
| VLP80-12 | 1/2"GAS | 300 | 80 |
| VLP80-34 | 3/4"GAS | 300 | 80 |
| VLP130-34 | 3/4"GAS | 300 | 130 |
| VLP130-10 | 1"GAS | 300 | 130 |
| Setting | ||
| Code | Standard setting bar (Q= 5l/min) |
Adj. pressure range bar |
| 00 | 40 | 5÷40 |
| 01 | 80 | 20÷100 |
| 02 | 180 | 40÷250 |
| 03 | 250 | 60÷350 |
Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm