OVC-SE-FM-SAE3000-SF-VLP200-114

Single effect OVERCENTER valve with brake unclamping and antishock valve, flangeable to Sae 1
OVC-SE-FM-SAE3000-SF-VLP200-114
Download the PDF
SAE FLANGE
OVC-SE-FM-SAE3000-SF-VLP200-114
Single effect OVERCENTER valve with brake unclamping and antishock valve, flangeable to Sae 1
Maximum flow 300 l/min
Maximum pressure 300 bar
Taratura
Code Standard setting
bar (Q= 5l/min)
Adj. Pressure range
bar
00 40 5÷40
01 80 20÷100
02 180 40÷250
03 250 60÷350
 
Setting The valve must be set at least 1.3 times maximum load induced pressure
Code Standard setting
bar (Q= 5l/min)
Setting range
bar
Spring color
01 100 20÷200 White
02 280 50÷350 Black

Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm