OVC2008-C

Pilot assisted overcentre valve, cartridge type
OVC2008-C
Download the PDF
CARTRIDGE
OVC2008-C
Pilot assisted overcentre valve, cartridge type
Maximum flow 30 l/min
Maximum pressure 350 bar
Standard pilot ratio 4:1
Pilot ratio upon request 3:1 8:1 10:1
Tightening torque 30÷35 Nm
 
Setting The valve must be set at least 1.3 times maximum load induced pressure
Code Standard setting
bar (Q= 5l/min)
Setting range
bar
Spring color
01 100 20÷200 White
02 280 50÷350 Black
 

Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm

Ordering examples: OVC2008C02

code
description
max. flow rate
max. pressure
cavities
3dfiles

(ordering initials)

l/min

gpm

bar

psi

OVC00539
OVC2008C02
30
7.93
350
5076
OVC00543
OVC2008C01
30
7.93
350
5076
OVC00673
OVC2008C02 140 BAR
30
7.93
350
5076