OVC-DE

Double effect overcentre valve
OVC-DE
Download the PDF
DOUBLE EFFECT
OVC-DE
Double effect overcentre valve
Max pressure 350 bar
Standard pilot ratio 4,25:1
Pilot ratio upon request 3:1 8:1 10:1
 
Type V,C Maximum flow [l/min]
OVC-DE-38 3/8" GAS 40
OVC-DE-12 1/2" GAS 70
 
Setting The valve must be set at least 1.3 times maximum load induced pressure
Code Standard setting
bar (Q= 5l/min)
Setting range
bar
Spring color
01 100 20÷200 White
02 280 50÷350 Black
 

Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm

Ordering examples: OVCDE3802, OVCDE3801D

code
description
max. flow rate
max. pressure
threads
3dfiles

(ordering initials)

l/min

gpm

bar

psi

OVC00155
OVCDE3801
40
10.57
350
5076
G3/8
OVC00156
OVCDE3802
40
10.57
350
5076
G3/8
OVC00157
OVCDE1201
70
18.49
350
5076
G1/2
OVC00158
OVCDE1202
70
18.49
350
5076
G1/2
OVC00191
OVCDE38F01
40
10.57
350
5076
G3/8
OVC00192
OVCDE38F02
40
10.57
350
5076
G3/8
OVC00193
OVCDE12F01
70
18.49
350
5076
G1/2
OVC00194
OVCDE12F02
70
18.49
350
5076
G1/2
OVC00571
OVCDE3802 R.P.10:1
40
10.57
350
5076
G3/8
OVC00585
OVCDE10S01
70
18.49
350
5076
10 SAE
OVC00586
OVCDE10S02
70
18.49
350
5076
10 SAE
OVC00799
OVCDE3802D
40
10.57
350
5076
G3/8
OVC00706
OVCDE3801D
40
10.57
350
5076
G3/8
OVC00705
OVCDE1202D
70
18.49
350
5076
G1/2