OVC-DE-C

Double effect overcentre valve - nipple screw flangeable
OVC-DE-C
Download the PDF
DOUBLE EFFECT
OVC-DE-C
Double effect overcentre valve - nipple screw flangeable
Max pressure 350 bar
Standard pilot ratio 4,25:1
Pilot ratio upon request 3:1 8:1 10:1
 
Type V1, V2, C2 Maximum flow [l/min]
OVC-DE-C-38 3/8" GAS 40
 
Setting The valve must be set at least 1.3 times maximum load induced pressure
Code Standard setting
bar (Q= 5l/min)
Setting range
bar
Spring color
01 100 20÷200 White
02 280 50÷350 Black
 

Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm

code
description
max. flow rate
max. pressure
threads
3dfiles

(ordering initials)

l/min

gpm

bar

psi

OVC00341
OVCDEC3801
40
10.57
350
5076
G3/8
OVC00342
OVCDEC3802
40
10.57
350
5076
G3/8
OVC00671
OVCDEC3802D
40
10.57
350
5076
G3/8