After assembly procedure the valves are respectively set at about 0.5mm (for G=1/4" gas and G=3/8" gas) and 0.7mm (for G=1/2" gas and G=3/4" gas).
| Type | G | A | B | C | D | E | H | R | ch | Torque Nm | Max flow l/min | Max pressure bar |
| VPN-14 | 1/4"GAS | 8.5 | 17.5 | 8 | 9.5 | 2.4 | 11 | 0.5 | 5.5 | 2 | 25 | 350 |
| VPN-38 | 3/8"GAS | 10.5 | 23 | 10.5 | 12.5 | 3.5 | 11 | 0.5 | 5.5 | 3 | 50 | 350 |
| VPN-12 | 1/2"GAS | 13 | 25 | 12 | 15 | 4.5 | 15 | 0.7 | 7 | 4 | 80 | 350 |
| VPN-34 | 3/4"GAS | 16 | 30.5 | 17 | 18 | 6 | 16 | 0.7 | 7 | 10 | 150 | 350 |
Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm
(ordering initials)
l/min
gpm
bar
psi