VREASB-12

Regenerative counterbalance valve with automatic shut-off
VREASB-12
Download the PDF
REGENERATIVE VALVE
VREASB-12
Regenerative counterbalance valve with automatic shut-off
Maximum flow 60 l/min
Maximum pressure 350 bar
Standard setting 350 bar
Adjustment pressure range 50 ÷ 350 bar
Max regenerative working pressure 115 bar
Pilot ratio 3:1

Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm

code
description
max. flow rate
max. pressure
threads
3dfiles

(ordering initials)

l/min

gpm

bar

psi

OVC00781
VREASB12
60
15.85
300
4351
G1/2"