RF-A-VLP10-EV

3 ways, pressure compensated flow regulator valve with relief valve and solenoid control
RF-A-VLP10-EV
Download the PDF
3 WAYS
RF-A-VLP10-EV
3 ways, pressure compensated flow regulator valve with relief valve and solenoid control
Type P, C, T Maximum inlet flow [l/min] Maximum regulated flow [l/min] Maximum pressure
[bar]
RF-A-VLP10-38-EV-B 3/8"GAS 60 35 270
RF-A-VLP10-12-EV-B 1/2"GAS 100 65 270
 
Relief valve setting
Setting 180 bar
Pressure adjustment range 40÷250 bar

Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm

code
description
max. flow rate
max. pressure
threads
3dfiles

(ordering initials)

l/min

gpm

bar

psi

RF000636
RFAVLP1012EVBB
100
26.42
270
3916
G1/2"
RF000730
RFAVLP1012EVBA
100
26.42
270
3916
G1/2"
RF000758
RFAVLP1012EVBC
100
26.42
270
3916
G1/2"
RF000783
RFAVLP1012EVBMA
100
26.42
270
3916
G1/2"
RF000873
RFAVLP1012EVBB 210 BAR 12 V CC DC + CONN
100
26.42
270
3916
G1/2"