| Type | P, B, C | Maximum pressure [bar] | Maximum flow [l/min] |
| RF-3-38 | 3/8" GAS | 300 | 40 |
| RF-3-12 | 1/2" GAS | 300 | 40 |
| Setting | |
| Setting code | Flow range l/min |
| 01 | 2÷6 |
| 02 | 5÷10 |
| 03 | 10÷18 |
| 04 | 20÷35 |
| Opzioni | |||
A![]() Vite esterna esagono incassato |
B![]() Volantino e dado |
C![]() Piombatura |
D![]() Cappellotto |
Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm
(ordering initials)
l/min
gpm
bar
psi