| Type | P, C, T | Maximum inlet flow [l/min] | Maximum regulated flow [l/min] | Maximum pressure [bar] |
| RF-A-VLP10-34-L | 3/4"GAS | 150 | 90 | 270 |
| RF-A-VLP10-10-L | 1"GAS | 280 | 190 | 270 |
| Relief valve setting | |
| Setting | 180 bar |
| Pressure adjustment range | 40÷250 bar |
Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm